Priority Member Itrademarket Priority 1st Year

MIKASE LABORATORY - PT MITRA KATIGA SEJAHTERA / AGENT DAN DISTRIBUTOR ALAT UJI KUALITAS UDARA, AIR, CUACA , KEBISINGAN SERTA GETARAN

http://itrademarket.com/mikaselaboratory/
  • Products Catalog

    CONTINUOUS PROCESS....

    Quantity Order:
    Add to Basket
    Origin:
    Canada
    Recommend to your friends Put on Product Partner

    Specification :

    The Nova 470 Series CH4 analyzers utilize a simple and reliable microprocessor-based non-dispersive infrared detector specific to CH4. The detector pulses an infrared beam of light through the sample tube, without the need for a mechanical chopper. In operation, the internal sample pump draws the sample gas through the filter/ condensate trap, secondary filter, flowmeter, and then on to the infrared detector. The detector output is digitally linearized and then displayed as percent or PPM CH4 on the digital meter. The output is also available as an analog or digital signal.

    Specifications
    Method of Detection
    Single cell NDIR with no moving parts
    Ranges Available
    470 - 0-1, 0-5, 0-10, 0-20, 0-30, 0-50, 0-100% CH4
    470L - 0-500, 0-1000, 0-3000, 0-5000, PPM CH4
    Resolution 0.1% CH4 on % versions, 1 PPM CH4 on PPM versions
    Accuracy & Repeatability 1% of full scale
    Drift Less than 2% of full scale per month
    Response Time ( T-90) Less than 15 seconds
    Ambient Temperature Range
    40 to 122° F ( 5 to 50° C) , Lower temperatures ( -5° F, -20° C) available with Cold Weather Package
    Linearity ± 1% of full scale
    Size & Weight
    Physical data will vary depending on enclosure style and options required
    Power 115 VAC, 60 Hz - 220 VAC, 50 Hz
    Output Options 4-20 mA into 500 ohms non-isolated standard
    Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs
    Alarms High and/ or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating, Low flow alarm
    Analyzer Type Continuous Online, Single Gas
    Hazardous Area Rating Options
    General Purpose, Non-Hazardous

    Applications
    For continuous analysis of methane ( CH4) in process gas streams using an infrared detector. Percent and PPM levels available as Models 470 & 470L respectively.

    Features
    PPM or percent CH4 by infrared detector
    Detector is sensitive, very reliable, and non-depleting
    Bright digital readout, 4-20 mA outputs
    Fast response ( T90 - less than 15 seconds)
    Microprocessor control for push button calibration
    Easy-to-maintain modular layout
    Built in sample pump, flowmeter, and filters

    Options
    Hi/ Low gas, low flow, and diagnostic alarms available
    Isolated analog, RS232, RS485, MODBUS, and Ethernet outputs available
    Sample conditioning systems available for removal of moisture, acidic gas, and dust
    Cabinet purge system available for use in hazardous areas
    One-step ' cal-now' button with touch screen LCD display
    Full automatic calibration with touch screen LCD display
    Cold weather package for operation to -5° F ( -20° C)
    Cabinet coolers can be fitted to most models
    Sensors mounted in temperature controlled heated box to improve accuracy
    High temperature filters and probes

    Calibration
    Easily zero checked on ambient air or nitrogen ( N2)
    Span using a known CH4 in nitrogen calibration gas.