    Specification :

    The Nova 430 Series Process Hydrogen analyzer utilizes a temperature-controlled TC cell for the detection of H2 in process gas. This cell produces a small millivoltage output which is directly proportional to the H2 detected. This output is then amplified and displayed on a digital readout meter and is also available as an output recorder. The analyzer can be supplied with a pump or pressure regulator depending on customer requirement.

    Specifications
    Method of Detection
    Temperature-controlled TC cell. Expected life in excess of 10 years. Cell cannot be burned out due to loss of sample flow
    Ranges Available Any range between 0-2% and 0-100% H2
    Resolution 0.1% H2 ( 0.01% H2 available)
    Accuracy & Repeatability ± 1% of full scale
    Drift Less than 1% of full scale per month
    Response Time ( T-90) 10-15 seconds to 90% step change
    Ambient Temperature Range
    32 to 122° F ( 0 to 50° C) , Lower temperatures ( -5° F, -20° C) with Cold Weather Package. Dew point should be at least 9° F ( 5° C) below lowest sample temperature
    Linearity ± 1% of full scale
    Size & Weight Dimensions will vary depending on enclosure style and options required
    Power 115 VAC, 60 Hz - 220 VAC, 50 Hz
    Output Options 4-20 mA into 500 ohms non-isolated standard
    Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs
    Alarms High and/ or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating
    Analyzer Type H2 Analyzer
    Hazardous Area Rating Options
    General Purpose, Non-Hazardous

    Applications
    For continuous analysis of up to 100% hydrogen ( H2) in process gas streams. Also recommended for other applications such as H2 cooled generators, electrolysis units, refinery gas, heat treating atmospheres, blast furnace gas, and many more.

    The Nova 430 Series Process Hydrogen analyzer utilizes a temperature-controlled TC cell for the detection of H2 in process gas. This cell produces a small millivoltage output which is directly proportional to the H2 detected. This output is then amplified and displayed on a digital readout meter and is also available as an output recorder. The analyzer can be supplied with a pump or pressure regulator depending on customer requirement.

    Features
    Best value continuous H2 analyzer
    Bright digital readout, 4-20 mA outputs
    Long life thermal conductivity ( TC) detector with high accuracy and repeatability, cannot be burned out from loss of flow
    Fast response ( T90 - 10 to 15 seconds)
    Easy-to-maintain modular layout
    Built in sample pump or pressure regulator
    Sensor mounted in temperature controlled heated box to improve accuracy

    Options
    Hi/ Low gas, low flow, and diagnostic alarms available
    Isolated analog, RS232, RS485, MODBUS, and Ethernet outputs available
    Sample conditioning systems available for removal of moisture, acidic gas, and dust
    Cabinet purge system available for use in hazardous areas
    One-step ' cal-now' button with touch screen LCD display
    Full automatic calibration with touch screen LCD display
    Cold weather package for operation to -5° F ( -20° C)
    Cabinet coolers can be fitted to most models
    High temperature filters and probes

    Calibration
    Nitrogen or air for zero
    Span using a known H2 in nitrogen calibration gas.